7×24 服务热线Sales hotline 400-151-0319 海外 / 手机(微信同号)Overseas / mobile (WeChat ID) +86 150-7688-0801 厂址Address:河北省邢台市南宫市经济开发区(西区)朝阳街2号No.2 Chaoyang St, West Zone, Nangong EDZ, Xingtai, Hebei
Products / 产品库 · 燃气调压计量撬

高压进来,稳压出去High pressure in, regulated pressure out

燃气调压撬:把 4.0 MPa 以下的高压气按级拆压到管网、锅炉或窑炉需要的出口压力,压力、温度、流量在撬上联动控制。Gas regulating skid: high pressure split stage by stage down to network, boiler or furnace pressure.

首页Home/产品中心Products/燃气调压计量撬Gas regulating and metering skid
燃气调压计量撬
01 / Overview

产品概述Product overview

调压计量撬是把一座调压站压缩进钢底座的产品:上游来气先过滤分离,经安全切断阀、调压阀组降压,中间按需加热(防止节流降温后结露或冰堵),再进计量段与加臭段,最后送往下游。DN5000 级撬体整重约 2100 kg,环境适应 −19~60℃,进出口压差在 0.4 MPa 量级时不需要中间加热。A whole regulating station compressed onto a skid: filtration, slam-shut, regulation, optional heating, metering, odorisation. 5000 Nm³/h unit weighs about 2100 kg.

配置逻辑有两派:单路大流量和双路一开一备。工业连续生产(窑炉、玻璃、陶瓷)必须双路,因为停气一次的损失远超设备差价;用气有明确停歇时段的场合,单路加旁通也能用。泰燃默认给双路,把切换做成自动,主路故障三秒内接替。Duty/standby is default for continuous industrial loads: changeover within three seconds on a fault.

燃气调压计量撬
调压计量撬:过滤器、调压器、流量计依次布置,取压点与放散口按规程留位。Regulating and metering skid: filter, regulator and meter in process order, with taps and vents per code.
A / Working principle

工作原理:调压器在做什么Working principle: what a regulator actually does

调压器的核心是一个力平衡:出口压力作用在膜片上,与设定弹簧的力相抗衡。出口压力升高,膜片被顶起,阀口随之关小;出口压力降低,弹簧把阀口推开。这个闭环不需要电、不需要控制器,靠机械反馈就能把出口压力稳定在设定值附近。A regulator is a force balance: outlet pressure acts on a diaphragm against a set spring. Rising outlet pressure lifts the diaphragm and closes the seat; falling pressure lets the spring open it. The loop needs no power and no controller — mechanical feedback holds the outlet near its set point.

单级调压的压比有限。进口压力高、出口压力低时,单级阀口流速过大,噪声、振动和阀口冲刷都随之出现。工程上按压比分级:压比大就用两级(一级监控、二级工作,或两级串联),并在级间设放散或监控切断,保证任何一级失效时下游压力仍受控。A single stage has a limited ratio. High inlet against low outlet means high seat velocity, noise, vibration and erosion. Practice splits the ratio: two stages — monitor plus working, or two in series — with interstage relief or a monitor that trips, so a failed stage cannot pass full inlet pressure downstream.

撬上通常还集成过滤、计量、超压切断、放散与远传。过滤器的意义在于保护阀口:一颗焊渣就足以让软密封阀口关不严。计量段的选择(涡轮、罗茨、超声波)取决于流量范围与贸易结算要求,而不是“哪个便宜”。Skids also carry filtration, metering, overpressure shut-off, relief and telemetry. Filtration protects the seat — a single weld slug is enough to keep a soft seat from closing. Meter type (turbine, Roots, ultrasonic) follows the flow range and whether custody transfer is involved, not price alone.

02 / Structure

结构组成What is on the skid

01
过滤分离器:旋风+滤芯两级,带差压表与排污。Two-stage filter-separator with differential gauge.
02
安全切断阀:超压/失压自动切断,手复位。Slam-shut on over/under-pressure.
03
调压阀组:工作调压器 + 监控调压器串联。Working and monitor regulators in series.
04
加热单元:电伴热或水套加热(按压差与露点确定)。Electric trace or water-jacket heating.
05
计量段:涡轮/罗茨流量计、整流器、温压补偿。Turbine or Roots meter with compensation.
06
加臭与放散:加臭机、安全放散阀、放散管。Odoriser, relief valve and vent.
07
控制柜:PLC、触摸屏、远程通信。PLC cabinet with HMI and telemetry.
燃气调压计量撬
户外成排布置,进出口同侧接管,门站用地更省。Outdoor skids in rows with inlet and outlet on the same side, saving city-gate footprint.
03 / Advantages

核心优势Why this design

  • 压差与露点先算后配:是否需要加热由计算决定,不凭经验堆设备。Heating decided by calculation, not habit.
  • 双路自动切换:3 秒内接替,连续生产不停气。Changeover within 3 s.
  • 计量可溯源:流量计选型与温压补偿一并出计算书。Meter sizing with compensation sheet.
  • 设计寿命 20 年:耐蚀材料 + 长效防腐工艺。20-year design life.
  • 智能电伴热:比常通加热省电 30% 以上。Smart trace heating saves over 30%.
Gallery / 产品图片

产品实拍Product photos

燃气调压撬 · 撬装出厂 1燃气调压撬 · 撬装出厂 2燃气调压撬 · 撬装出厂 3

燃气调压撬 · 撬装出厂Gas regulating skid — skid-mounted 点击图片放大查看。 Click to enlarge.

Models / 规格与实拍

按规格挑,点进去看现场实拍Pick a size, see the site photos

同一个型号,照片比文字更能说明做工:撬体骨架、管路走向、阀组排布、接地点和保温层都在里面。选一个规格,进去看它在车间和现场的实拍。Skid frame, piping runs, valve layout and insulation, shown as built.

04 / Specification

技术参数Technical data

参数城市门站 RX 系列
型号范围RX-100 ~ RX-14000(按公称流量选,A/B/C/D/E 为结构代号)
进口压力0.05–4.0 MPa(高压段可达 10 MPa 设计)
出口压力3–30 kPa / 0.02–1.0 MPa / 0.1–4.0 MPa(按管网)
流量100 ~ 14000 Nm³/h
压力调节单路、双路、多路
超压保护监控 + 切断 + 放散
计量方式涡轮、孔板、超声波
加热方式电加热 / 热水 / 蒸汽(按需)
响应时间ta ≤ 1 s
远程与通讯RS232 / RS485 / 无线电;可配 RTU 与通讯单元

撬装式结构,用于长输管线分输站、首站下游或城市中压管网上游,具备净化、计量、调压、分配与安全保护功能。

以上为常规配置参数,取自公司产品画册;流量、介质、进出口压力与接口不同时按工况单独设计,以合同技术文件为准。

B / Selection

选型与计算要点Selection points

01
按高峰流量选口径,按最小流量校核精度 调压器口径按高峰小时流量选,但计量与调压的精度要在最小流量下校核。只按最大值选型,低负荷时会出现“大马拉小车”,计量偏差与调节抖动都会出现。Size on peak flow, check accuracy at minimum Seat size follows peak hourly flow; accuracy must be verified at minimum flow. Sizing only on the maximum leaves the station oversized at low load, with metering error and hunting.
02
压比与级数 中压进、低压出一般单级即可;次高压或高压进、低压出建议两级,并在级间设监控。级数不是越多越好,每一级都带来压损与维护点。Ratio and number of stages Medium-pressure inlet to low-pressure outlet usually needs one stage; high or sub-high inlet to low outlet is better with two plus a monitor. More stages mean more pressure loss and more maintenance points.
03
超压保护的三道闸 安全切断阀(超压即切断)、监控调压器或安全放散阀、以及出口管路上的机械放散。三层不是冗余浪费,而是规范要求的分级保护,任何一层失效都还有下一层。Three layers of overpressure protection A slam-shut valve, a monitor regulator or relief, and mechanical relief on the outlet line. Three layers are not redundancy for its own sake — they are the graded protection the codes expect.
04
箱体与防爆 调压柜要考虑通风、放散口朝向、防爆等级与冬季伴热。户外柜还要考虑雨雪与日晒对膜片与仪表的影响;北方项目建议电伴热或保温。Enclosure and Ex rating Cabinets need ventilation, vent orientation, an Ex rating and winter heat tracing. Outdoors, rain, snow and sun affect diaphragms and instruments; northern sites should specify tracing or insulation.
05
口径与流向 进出口法兰标准、口径与流向在合同阶段确认。撬体上流向标识、阀门手轮方向都要与现场一致,避免运维误操作。Connections and flow direction Flange standard, size and flow direction are fixed at contract stage, and the marking on the skid must match site practice to avoid mis-operation.
05 / Duty

适用工况Typical duties

城市门站与分输站City gate and offtake工业园集中调压Industrial park regulation窑炉、玻璃、陶瓷连续生产Continuous furnace supplyCNG 上载与管网接入CNG uploading
Fit / 适用与边界

适合什么工况,什么情况不适用Where it fits, and where it does not

这套设备适合Best for

  • 调压、计量、加臭可集成一撬,减少界面Regulation, metering and odorisation on one skid
  • 双路一备,故障自动切换Duty / standby with automatic changeover
  • 模块化扩展,后期增容不必整撬更换Modular; capacity can be added later
  • 压力、流量可远传,接入站控Pressure and flow can feed SCADA

需要提前确认的边界Check before ordering

  • 需与上下游管网压力匹配,压差过大要分级Must match network pressures; large drops need staging
  • 贸易计量装置需按当地计量规定检定Custody meters need local metrological verification
  • 含加臭时需办理相关手续并定期补充臭剂Odorisation needs permits and regular refill
Configuration / 标准配置

标准配置Standard configuration

进口过滤Inlet filtration双路过滤器,压差可监测Twin filters with differential-pressure monitoring
调压Regulation双路一备,工作路故障自动切换Duty / standby with automatic changeover
计量Metering涡轮、罗茨或超声流量计,按结算精度选型Turbine, Roots or ultrasonic meter to custody accuracy
加臭Odorisation按需要配置加臭装置,注入量可调Optional odorant injection with adjustable rate
超压保护Overpressure protection安全切断阀与放散阀联动Slam-shut interlocked with relief
远传Telemetry压力、流量、阀位信号上传Pressure, flow and valve position to SCADA
撬体Skid整体撬装,管路段设支撑与检修空间Skid-mounted with supports and maintenance clearance

以上为常规配置,实际随机组按工况与用户管网条件确定,可按需增减。Standard scope shown; final scope is set by duty and network conditions, and can be adjusted.

Components / 主要零部件

主要零部件Main components

调压器Regulator双路一备,出口压力稳定Duty / standby, stable outlet
过滤器Filter保护阀口与计量装置Protects seats and metering
流量计Flow meter贸易计量,精度按结算要求Custody metering to settlement accuracy
安全切断阀Slam-shut超压切断,防止下游超压Cuts off on overpressure
放散阀Relief valve定压放散Set-pressure relief
变送器Transmitters压力、差压、温度信号Pressure, differential and temperature signals
控制柜Control cabinet数据采集与远传Data acquisition and telemetry

零部件的品牌与型号按项目技术要求与用户指定品牌确定,页内不限定具体厂家。Brand and model are fixed by project specification and the user's approved vendor list.

C / FAQ

常见问题FAQ

出口压力慢慢往上爬是什么原因?Why does outlet pressure creep up?

多半是阀口有杂物导致关不严,或阀座密封老化;也可能是取压管内有积液。先排污、再检查取压管路,最后才考虑换阀芯。Debris on the seat, an aged seat seal, or liquid in the sensing line. Blow down, check the sensing line, and only then consider a new seat.

调压器“嗡嗡”响正常吗?Is a humming regulator normal?

轻微气流声正常;持续啸叫说明流速过高或阀口选大了,需要重新核算压差分配或换小口径阀芯。Light flow noise is normal; sustained whistling means excessive velocity or an oversized seat — re-check the ratio split or fit a smaller trim.

能不能只装调压器不装切断阀?Can the slam-shut be omitted?

不建议,也不符合规范要求。下游超压的后果远大于一台切断阀的成本。Not advisable and not compliant. The cost of a slam-shut valve is trivial against the consequence of downstream overpressure.

冬天取压管结冰怎么处理?What if the sensing line ices up?

加伴热与保温,或把取压点移到温度更稳定的位置。结冰会让调压器“读错压力”,表现为出口压力异常升高。Trace and insulate it, or move the tap to a warmer location. An iced sensing line makes the regulator read the wrong pressure, usually driving the outlet high.

柜内可以放计量吗?Can metering sit inside the cabinet?

可以,计量撬与调压柜一体化很常见;但要给计量段留检修空间与校验接口,别把柜子做满。Yes — integrated regulating and metering cabinets are common — but leave service space and a calibration port for the meter.

07 / Related

同类设备Related equipment

把你的工况发过来,我们出选型表Send your duty, we return a selection sheet

需要提供:介质、最大/最小流量、进口压力、出口压力、现场热源(电/热水/蒸汽)、安装场地条件。We need medium, min/max flow, inlet and outlet pressure, available heat source and site conditions.